We offer a variety of courses in the design, installation and servicing of our Zuba-Central, M-Series, P-Series and City Multi systems. A list of the courses can be found below.

Please contact your local distributor for information on our specialized courses or on our regional training which is routinely held throughout Canada.

Zuba Central - Service and Troubleshooting
Course ID: ZAC-02 Duration: 1 Day

This 1 day course is a follow up to ZAC-01 (zuba central introductory course) developed to enhance the comprehensive electronic and refrigerant control sequence of the zuba central heat pump system.

An in-depth coverage of the electronic and refrigerant sequence of operation will be carried out. Participants will be taught how to read and understand the wiring diagram, with notation of the expected control voltages and signal corresponding to the sequence of operation. The refrigerant circuit operation and control sequence will be covered in details with reference to the corresponding temperatures and pressures during normal operation.

This course will also incorporate hands on lab sessions to aid in the understanding of the electronic and refrigerant circuit description of operation. Participants will work on several lab stations, performing troubleshooting and diagnostics related to the operation of the major components of the zuba central heat pump system.

Attendants who have successfully completed the course will be granted Mitsubishi MEQ dealer status

Dates and Locations - 2015 Detail Course Description

P-Series R410A - Installation & Troubleshooting
Course ID: PAC-02 Duration: 1 Day
This one day certificate course provides an overview of the new P-Series technology for large residential and light commercial applications as well as in-depth coverage of the installation and commissioning considerations for the new Variable Compressor Speed Inverter (VCSi) technology and functional overview of these systems. This course will also cover installation procedures, service and hands-on troubleshooting techniques.
Dates and Locations - 2015 Detail Course Description

Mr.Slim M and S series R410A - Installation & Troubleshooting
Course ID: MRAC-01 Duration: 1 Day
This one day certificate course provides an overview of the Mr.Slim M and S Series technology for residential applications as well as in-depth coverage of the installation and commissioning considerations for the new Variable Compressor Speed Inverter (VCSi) technology and functional overview of these systems. This course will also cover installation procedures, service and hands-on troubleshooting techniques.
Dates and Locations - 2014 Detail Course Description

City Multi R410A - Installation and Commissioning (Beginner)
Course ID: CM-01 Duration: 2 Days

This 3-day course introduces key practices of system design and installation and commissioning with main focus on Installers, Contractors and Service personnel including introduction to line-up, features and benefits of all types of City Multi (CM) systems.

This course covers system design, control wiring, unit addressing, piping requirements, refrigerant charge calculation and other key steps involved in a successful installation and commissioning of a CM system.

It covers installation procedures, basic troubleshooting and the use of advanced software like Design Tool for model selection and basic Maintenance Tool for checking system performance and general diagnosis.

It also provides trainees with hands-on training on wiring (power and control), addressing, and general start-up procedure and commissioning and basic troubleshooting.

Dates and Locations - 2016

City Multi R410A - System Troubleshooting and Advanced Controllers (Advanced)
Course ID: CM-02*
*CM-02 is offered only to those trainees who have acquired the capability of CM-01.
Duration: 3 Days

This 3-day course provides an in-depth understanding of system, proper commissioning, troubleshooting and advanced controllers to Installers, Contractors and Service personnel.

This course provides understanding of circuit and control algorithm to understand the main operation logic of CM system and a complete understanding of advanced controllers along with system integration.

It provides a complete understanding of Maintenance tool software and all critical troubleshooting procedures.

It also includes hands-on training on dip-switch setting, advanced controller's set-up that also includes 3rd party device control and troubleshooting of the system.

Dates and Locations - 2016